Wilsonart® SR605 Fire-Rated Laminate Technical Data 1. Manufacturer Wilsonart International 2400 Wilson Place P.O. Box 6110 Temple, Texas 76503-6110 Phone: (254) 207-7000; (800) 433-3222 Fax: (254) 207-2384 Web Site: www.wilsonartlaminate.com 2. Product Description Recommended Uses: SR605 Fire-Rated Laminate is recommended for interior surfacing on computer floors in commercial and military applications where fire codes specify or the environment suggests a fire-resistant and smoke-resistant surface. It may be applied as decorative surfacing for commercial computer room floors, marine computer floors (false decks), telephone facilities, hospitals, laboratories, institutional bleacher seating, elevator flooring, ambulance flooring, decorative chair pads, clean room floors, operating room floors, and other heavy traffic areas. This laminate with the added benefit of an extra-wear surface provides a high resistance to scuffing, cigarette burns, and heel marks. The material also has a skid resistant surface. SR605 Fire-Rated Laminate can offer a Class I or A fire rating, provided fire-retardant adhesives and substrates are used. • General Purpose (HGF) Type SR605: Produced for both horizontal and vertical applications where the surface must perform under constant use. NOTE: Fire-Rated Backer Type 266 is recommended as a stabilizing backer sheet for applications where the decorative surface is General Purpose Type SR605. Product Composition: The decorative surface is composed of high-wear melamine resin-treated decorative surface papers. Special kraft core sheets, used to obtain the desired thickness, are impregnated with phenolic resin. Basic Limitations: Wilsonart Laminate is intended for interior use only, and should be protected from continuous exposure to direct sunlight, extremes in humidity and temperatures greater than 275rF (135FC). It is not structural material and must be bonded to a suitable substrate. Wilsonart Laminate should not be used as direct covering for plaster or concrete walls, or for gypsum wallboard. It should not be exposed to flame, molten metal, metallic sparks or intense, direct sunlight. Nor should it be used as a cutting surface. Pattern and Color Availability: Wilsonart Fire-Rated SR605 Laminate is available in the patterns listed below. D328 – Larkspur Order as: D328S-60-605 *4303 – Grey Mirage Order as: 4303S-60-605 4552 – Ebony Star Order as: 4552S-60-605 4646 – Blue Moraine Order as: 4646S-60-605 *Available until current paper inventory depleted. Finishes: • 60 Matte A textured finish with a moderate reflective quality. Glossometer reading: MD and CD 10 1 2. NOTE: Glossometer readings are made at a 60N angle of incidence. MD means the machine direction of a laminate sheet and CD refers to the cross direction. Sheet Sizes 48" x 96" (1219mm x 2438mm) 48" x 120" (1219mm x 3048mm) Sheet Thicknesses Type Typical Wilsonart Thickness NEMA Thickness Weight PSF General Purpose Type SR605 (HGF) 0.048" ± 0.005" (1.22mm ± 0.13mm) 0.048" ± 0.005" (1.2mm ± 0.12mm) 0.438# NOTE: Minimum sheet order requirements: 2 sheets by size and pattern. 3. Technical Data Physical Properties of Fire-Rated Laminate NEMA Test Typical Wilsonart Type SR605 (HGF) NEMA Standard HGF Surface Wear Resistance (cycles) 5,000 3,000 (min.) Boiling Water Resistance No effect No effect High Temperature Resistance No effect Slight effect Stain Resistance Reagents 1-10 Reagents 11-15 No effect Slight effect No effect Moderate effect Dimensional Stability Machine Direction Cross Direction 0.18% 0.67% 0.50% (max.) 0.90% (max.) Impact Resistance 40" (1016mm) 35" (889mm) Cleanability (cycles) 15 25 (max.) Appearance No ABC defects No ABC defects Note: Since Fire-Rated backer sheets are not intended to be exposed to light, wear or everyday use, no physical property tests are in current use. Typical Coefficient of Friction Test Data Test data for Wilsonart SR605 Fire-Rated Laminate is obtained by the American Society for Testing Materials (ASTM C 1028, Determining the Static Coefficient of Ceramic Tile and Other Like Surfaces by the Horizontal Dynamometer Pull-Meter method. NEMA Type Wilsonart Product Dry Test Conditions Results Wet Test Conditions Results HGF SR605 0.69 0.65 NOTE: A coefficient of friction value of 0.5 or greater is generally accepted for classifying a walking surface as slip resistant. Typical Fire Test Data Test data for Wilsonart SR605 Fire-Rated Laminate is obtained by the Steiner Tunnel Test method of the American Society for Testing Materials (ASTM E 84, Standard Test Method For Surface Burning Characteristics of Building Materials). This procedure is cataloged by Underwriters Laboratories, Inc. as UL 723. Typical Flame Spread and Smoke Developed Properties NEMA Type Wilsonart Product Unbonded Bonded to Incombustible Cement Board Bonded to Fire-Rated Particleboard HGF SR605 15/15 15/0 15/25 Note: Adhesive to attain Flame Spread and Smoke Developed figures for bonded laminates (above) is resorcinol. Fire-rated particleboard is Duraflake, with a UL rating of 25/25, or comparable material. The above values are CUL approved. Model Code Designations used to determine flame spread classification Flame Spread Classification (Maximum Rating) International (IBC) Life Safety (NFPA 101) 25 A A 75 B B 200 C C (Reference: Architectural Woodwork Quality Standard, 8th Edition, Version 1.0 – 2003) All Model Codes regulate the generation of smoke by interior finish material. In all cases they specify a maximum smoke development rating of 450. Codes and Certifications: General Fire Code Compliance Test data for code compliance is from the UL 723 Tunnel Test method. This procedure has been cataloged under the following designations: American Society for Testing Materials ASTM E 84 American National Standards Institute ANSI No. 2.5 National Fire Protection Agency NFPA No. 255 Underwriters Laboratories, Inc. UL No. 723 This test data is the basis for fire codes written by various responsible groups, including: BBC Basic Building Code (Building Officials Conference of America. Used in Midwest and Northeast.) NFPA National Fire Protection Agency (Building Exits Code, Section #101.) SSBC Southern Standards Building Code (Southern Building Codes Congress. Used primarily in the South.) Many local codes, especially in densely populated areas, have been patterned after these. Examples include the cities of Los Angeles and San Francisco and the Port Authority of New York. Approvals include: New York City, Department of Buildings, Materials and Equipment Acceptance (Types 264, 266, 604, 605 & 607) MEA 167-87M General Standards Fire-Rated Laminate conforms to ANSI/NEMA LD3-2005 for HGF (Type SR605). The GREENGUARD Environmental Institute™ has awarded its GREENGUARD Indoor Air Quality Certification to Wilsonart Laminate. All Wilsonart Laminate product types were tested under the stringent GREENGUARD Standards for low-emitting products. All GREENGUARD Indoor Air Quality Certified® products ensure minimal impact on the indoor environment. For a copy of the certificate, visit www.greenguard.org. Specific Product Standards Fire-Rated Laminate meets the following federal codes: Aircraft Interiors. U.S. Federal Test Method, Federal Aviation Administration, DOT, Part 25.853, Airworthiness Standards: Transport Category Airplane (Interior Finish). Fire-Rated Laminate Types 604, 605 and 607 comply with parts A and C. Military/Ships. U.S. Military Standard MIL-P-17171E (SHIPS) Plastic Laminate and U.S. Military Standard 1623D (SHIPS), “Fire Performance Requirements and Approval Specifications for Interior Finished Materials and Furnishings - Naval Shipboard Use.” Fire-Rated Laminate Types 605 and 607 comply with both of these standards. Military/Ships Fire-Rated Product Type U.S.C.G. (46 CFR 164.012) U.S.C.G. (IMO FTP Code) Canadian Board of Steamship Inspection Type SR605 164.012/105/0 164.112/9/0 G1-166 Type 605 also appears on the U.S. Department of the Navy “Approved Habitability Materials List 9640, SER 05M1.11/1148,” (Revision K, May 1996), Pages 3 and 4, paragraphs 1.5 and 2(b), for use on bulkhead sheathing, and on NAVSEA Drawing #804-5000991. Mobile Homes U.S. Federal Register August 9, 1984, Housing and Urban Development Mobile Home Construction and Safety Standard (24CFR), 3280.203. Fire-Rated Laminate Types 604, 605, 607, 264 and 266 comply. Motor Vehicles/Interiors U.S. Federal Motor Vehicle Safety Standard (FMVSS) 302, “Flammability of Interior Materials.” Fire-Rated Laminate Types 604, 605 and 607 comply. 4. Installation: Fabrication and Assembly Recommendations WilsonartW SR605 is designed for application to oil-free Nomex honeycomb, aluminum honeycomb, plywood, steel, or particleboard computer floor sections with a moisture-resistant adhesive in accordance with the adhesive manufacturer’s recommendations. Bonding to a Nomex honeycomb core requires the use of a MIL-approved adhesive. Contact the computer floor system installer and/or Nomex panel manufacturer for the thickness of computer floor laminates required and further installation instructions. Take care to ensure an appropriate moisture balance between the laminate and the substrate prior to fabrication. The face and backing laminates and the substrate should be conditioned in the same environment for 48 hours before fabrication. Recommended conditioning temperature is about 75RF (24F C). Laminates should be conditioned at 45% to 55% relative humidity. To avoid stress cracking, do not use square-cut inside corners. All inside corners should have a minimum of 1/8" (3.18mm) radius, and all edges should be routed smooth. 5. Warranty Wilsonart International warrants that, under normal use and service, the material and workmanship of its laminate shall conform to the standards set forth on the applicable technical data sheets for a period of one (1) year from the date of sale to the first consumer purchaser. Dealers and distributors are provided with the technical data sheets which contain specific standards of performance for the products. In the event that a laminate product does not perform as warranted, the first consumer purchaser's sole remedy shall be limited to repair or replacement of all or any part of the product which is defective, at the manufacturer's sole discretion. This warranty applies only to product: 1. In its original installation; and 2. Purchased by the first consumer purchaser. This warranty is not transferable, and expires upon resale or transfer by the first consumer purchaser. This warranty shall not apply to defects or damage arising for any of the following: 1. Accidents, abuse or misuse; 2. Exposure to extreme temperature; 3. Improper fabrication or installation; or 4. Improper maintenance. NO OTHER WARRANTIES, EXPRESS OR IMPLIED, ARE MADE, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. UNDER NO CIRCUMSTANCES SHALL WILSONART INTERNATIONAL, INC. BE LIABLE FOR ANY LOSS OR DAMAGE ARISING FROM THE PURCHASE, USE OR INABILITY TO USE THIS PRODUCT, OR FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. NO FABRICATOR, INSTALLER, DEALER, AGENT OR EMPLOYEE OF WILSONART INTERNATIONAL, INC. HAS THE AUTHORITY TO MODIFY THE OBLIGATIONS OR LIMITATIONS OF THIS WARRANTY. This warranty gives you specific legal rights, and you also may have other rights that vary from state to state; therefore, some of the limitations stated above may not apply to you. It is to your benefit to save your documentation upon purchase of a product. 6. Maintenance* The decorative surface may be cleaned with warm water and mild soaps, such as those used for hands or dishes. Do not use cleansers that contain abrasives, acids or alkalis; they will damage the decorative surface. Remove stubborn stains with a 1 1/2-minute exposure to hypochlorite bleach such as Clorox®, followed by a clean water rinse. We recommend that you not allow any of the following reagents to remain in contact with the decorative surface: 1. Hypochlorite bleach, except as described above 2. Hydrogen peroxide solution 3. Mineral acids, hydrochloric acid such as Lime-A-Way™, sulfuric or nitric acid 4. Caustic solutions containing greater than 2% lye, such as Drano® 5. Sodium bisulfate, such as Sani-Flush® 6. Potassium permanganate 7. Berry juices 8. Silver nitrate, in 1% concentration 9. Gentian violet 10. Mild silver protein, such as 20% argyrol 11. Bluing 12. Fabric dye, such as Tintex® or Rit® 13. Alcohol containing 1% iodine in solution If you require a laminate that can withstand these and other chemicals, please refer to the tech data for Wilsonart® Chemsurf® Chemical-Resistant Laminates. *Not applicable for Phenolic Laminate Backing Sheets. Free copies of the “Care and Maintenance Guide,” which covers all Wilsonart products, are available. The guide can be accessed at http://www.wilsonartlaminate.com or by calling our hotline at: 800-433-3222. It can be used for your own information, for project manuals, and for provision to clients and contractors involved with interior construction and finishing. 7. Technical Services For samples, literature, questions or technical assistance, please contact our toll-free Hotline at (800) 433-3222, Monday through Friday, 7 am –7 pm, CST. Specification Form: Surface shall be Wilsonart Laminate, produced by Wilsonart International, Temple, Texas 76503-6110. Type: See Fire-Rated specific types under Product Description/Product Definition Surface Color Number: ___________ Color Name: ___________ Finish Number: ___________ Name: ___________ Edge Trim Color Number: ___________ Color Name: ___________ Adhesive Name: ___________ Grade/Type: ___________ Brand: Wilsonart Adhesive Material shall equal or exceed performance standards set by the American National Standards Institute/National Electrical Manufacturers Association (ANSI/NEMA) LD3-2005 for high-pressure laminate. Fabrication shall comply with “Architectural Woodwork Quality Standards, Guide Specifications and Quality Certification Program” guidelines of the Architectural Woodwork Institute. Fire Rated TD (TD0100) Revised: July 20, 2007 © 1998-2007, Wilsonart International, Inc. 8 4 1